USING TERMINATION BARS TO JOIN TO OTHER ROOFS
Training hub – all your questions answered!
For the best results, please follow the instructions as detailed below.
If you still have questions please feel free to contact us using the form hereā¦
STEP 1
Overlap the FlexiProof EPDM membrane onto the adjoining flat roof system by 60 mm.


STEP 2
Lift up the FlexiProof EPDM membrane to expose the adjoining roof system and apply a thick bead of water block mastic the length or the overlap.
STEP 3
Flap the FlexiProof membrane onto the water block mastic and fit the termination bar over the top using self sealing screws to create a compression seal.


STEP 4
Remove any excess membrane using a craft knife and seal off the termination bar edge using EPDM edge sealant.
Please note! When joining to existing felt with embedded stones ensure all stones are removed back to a smooth surface prior to application of water lock mastic. In the case of jointing to other single-ply roofs and EPDM ensure existing surfaces are cleaned using membrane cleaner.